JavaScript is not enabled.
sold me wrong part - Review by citysearch c | Par's Sales & Service

Par's Sales & Service

Claim

sold me wrong part 10/10/2007

They correctly diagnosed the problem for my ge range, It wouldn't lite, but sold me the wrong part, a carborundum igniter, which doesn't put out enough current to open the gas safety valve. I had to cut the wires to put the old plug on so now I'm stuck with it. Now I have to buy a Norton.\r \r \r Each type of ignitor has a different operating current rating and the appropriate model bimetal gas valve\r must be used: NORTON ignitors limit the operating current flow in the circuit to 3.2 to 3.6 amps.\r CARBORUNDUM ignitors limit the operating current flow in the circuit to 2.5 to 3.0 amps.\r (A special ?powder-blue? flat ceramic NORTON model is available as an adaptive replacement for many CARBORUNDUM models). more